oil sealing device

基本解释油封装置(氢冷发电机的)

网络释义

1)oil sealing device,油封装置(氢冷发电机的)2)hydrogen-cooled generator,氢冷发电机3)hydrogen cooled generator,氢冷发电机4)hydrogen cooling generator,氢冷发电机5)generator package,发电机封装6)hydrogen-cooled turbogenerator,氢冷汽轮发电机

用法和例句

After analyzing the cause and harmfulness of excessive moisture in hydrogen for hydrogen-cooled generator, some correction measures and precautions are proposed based on the real conditions of hydrogen cooled generators in Southern Hebei Network.

文章对氢冷发电机氢气湿度超标的成因、危害进行了分析 ,并结合河北南网氢冷发电机组的实际情况提出了治理措施和需要注意的问题。

An introduction is being presented to the function,structure and features of 2 sealing oil systems for hydrogen-cooled generators of domestic 1 000 MW nuclear power stations.

介绍了国内1000MW核电站氢冷发电机使用的2种密封油系统的功能、结构和特点,并进行综合分析比较,指出单流环密封结构简单,又具有油、水分离装置,运行安全可靠;双流环密封结构复杂,但运行比较灵活。

The cause and harm of high moisture contained in the hydrogen gas of a hydrogen cooled generator in Guodian Zhejiang Beilun No.

对国电浙江北仑第一发电有限公司600 MW氢冷发电机中氢气湿度偏高的原因、危害进行了分析。

The seal oil system has become weaker part for hydrogen cooled generator in running.

轴封油系统已成为氢冷发电机运行的薄弱环节。

Hydrogen leakage, which is frequent and with high-risk, severely threatens the operation of hydrogen cooling generator.

漏氢是氢冷发电机运行中发生频率较高且危害性很大的事件,严重影响了机组的安全运行。

The seal oil following error of two 200 MW hydrogen cooling generator units oil seal system many a time and the cause of sealing gasket cracked are analyzed in Xinyu power company of limited liability.

分析了新余发电有限责任公司两台 2 0 0MW氢冷发电机组密封油系统多次出现的密封油跟踪不良及密封瓦壳垫子破裂缺陷的原因 ,提出了改进意见 ,同时就处理密封油管道清洗和消除密封油压摆动问题的经验进行交

The existing problems in the hydrogen dryer of QFSN-300-2-20 type hydrogen cooling generator are analysed, the rebuilding scheme of adopting QGZ-3 type hydrogen dryer device is recommended and the state of practice is described.

分析了QFSN - 30 0 - 2 - 2 0氢冷发电机氢气干燥器存在的问题 ,提出了采用新型QGZ - 3型氢气干燥装置的改造方案并介绍了实施情

At the same time,the actual example of gastight test of hydrogen-cooled turbogenerator of Hardian company is given in this paper.

介绍以LabWindows/CVI为平台开发研制的高度自动化的气密试验分析仪可实现数据的自动采集和处理,使试验结果更准确、可靠,本文给出哈电公司氢冷汽轮发电机气密试验试验实例。

This paper analyzes the causes of the shafting vibration of a Chinese-made 300 MW unit after overhauling,coming to the conclusion that the assembly quality of the hydrogen sealing bush in the hydrogen-cooled turbogenerator has great influence on vibration.

分析的结果是氢冷汽轮发电机的氢气密封瓦的装配质量对振动有显著影响。

Safety Analysis on Vacuum Method Putting Hydro-gen In and Out for Hydrogen Cooled Generator

氢冷发电机真空法投排氢的安全分析

Hydrogen Leakage Treatment of 600 MW Hydrogen-cooling Generator and Its Precautionary Measure

600MW氢冷发电机漏氢处理及预防措施

Research and Application of the Large Capacity Hydrogen-Cooling Generator H_2 Control System;

大型氢冷发电机氢气控制系统的研究和应用

Analysis on the Overheat Fault of an Hydrogen Cooled Generator Rotor

一台210MW氢冷发电机转子过热故障分析

Comparison of 2 Sealing Oil Systems for Hydrogen-cooled Generator of Domestic 1000MW Nuclear Power Stations

国内百万千瓦核电站氢冷发电机2种密封油系统的比较

DISPOSAL OF HYDROGEN LEAKAGE FROM 300 MW HYDROGEN COOLED TURBO-GENERATOR SET

300MW氢冷汽轮发电机组漏氢处理

Adsorption Hydrogen Gas Dryer Unit Based on PLC

汽轮发电机氢冷系统新型除湿装置的开发

An Instrument Developed to Detect the Hydrogen Leakage into the Cooling Water of the Stator Bar of Turbogenerators

汽轮发电机定子线棒冷却水漏氢巡回检测仪

water cooled diesel generator set

水冷式柴油发电机组

condensing turbo-generator set

冷凝式汽轮发电机组

Performance Study on Mixing Fuel-Hydrogen Combustion on Electronic Controlled CNG Engine;

电控CNG发动机掺氢燃烧性能研究

The cause analysis and treatment of larger hydrogen humidity of generator

发电机氢气湿度大的原因分析及处理

Resolusion of H_2 Leakage from the Outlet Lead Sleeve of the 300MW Generator

300MW发电机出线套管漏氢的根治

The Cause Analysis and Solution of Hydrogen-cooled Generator Hydrogen Purity Decline

发电机氢气纯度下降原因分析及处理

Gas Leakage Test and Calculation of Hydrogen Leakage of 600MW Generators

600MW发电机气体泄漏试验及漏氢量计算

Generator hydrogen data management system Based on VB

基于VB的发电机氢气数据管理系统

Experimental Study on Heat Transfer Performance of the Condenser for Evaporative Cooling Turbo-generator

蒸发冷却汽轮发电机冷凝器传热特性试验研究

Reasons of tube burst by hydrogen-induced corrosion for No.3 boiler water wall in Fulaerji electric power general plant

富拉尔基发电总厂3号炉水冷壁管氢腐蚀爆管原因分析

最新行业英语