On the basis of analyzing the climate performance in the hot summer and warm winter zone,the thermal performance of typical residential building walls in this district is experimented and the coefficient factor of heat transfer and index of thermal inertial are derived by these experimentdata.
在分析夏热冬暖地区热工气候特点的基础上,对该地区典型居住建筑的墙体热工性能进行了详细的实验测试研究,得出了其传热系数、热惰性指标和厚度对其热工性能参数的影响规律,摸清了该地区典型居住建筑墙体热工性能基本特点,找出了其热工性能参数随厚度的变化规律。
To combine with the actuality of building energy conservation in our country and climate characteristic in hot summer and warm winter zone,interior heat environment condition of existing buildings in this area was analyzed.
结合我国建筑节能现状和夏热冬暖地区的气候特征,分析了该地区既有建筑的室内热环境状况,指出了围护结构热工性能不足是导致该地区既有建筑耗能过大的原因。
Discussion on natural ventilation in hot summer and warm winter zone of Fujian;
福建省夏热冬暖地区建筑夏季自然通风的分析及探讨
Based on a Building Department Model Construction,the method,the question should be paid attention to and the verification of energy efficiency in-site testing of building envelope in hot summer and warm winter zone that in different season and environmental condition is introduced.
本文以某建设部示范工程为例,介绍在夏热冬暖地区不同季节、环境条件下进行现场围护构造检测方法和注意事项,以及对检测结果进行验证,并探讨现场围护构造热工性能检测运用于常规建筑节能验收的可行性。
Then,some measures of energy saving for office builings are put forward in accordance with the condition of weather,economy and environment at the hot summer and warm winter zone.
夏热冬暖地区具有自身的特点,以深圳特区为例,分析夏热冬暖地区办公建筑的耗能现状,提出符合夏热冬暖地区气候、经济、环境条件的办公建筑设计的节能措施。